A buyer’s guide to the jargon behind refurbished, used, and certified medical devices—so you can compare offers fairly and buy with confidence.

Contents
Why Terminology Matters
Pre-owned medical equipment can deliver substantial savings without compromising patient safety—if you understand the language sellers use. Terms like “refurbished,” “OEM,” “patient-ready,” or “as‑is” directly affect risk, total cost of ownership, and compliance. This guide decodes the most common phrases so you can compare apples to apples across quotes.
Condition Terms: “Used” vs. “Refurbished” vs. “Certified”
Condition labels describe how much work has been done to a device before resale. Because definitions can vary by seller, always ask for the documented process behind the label.
Term | Typical Meaning | What You Should Expect | Risk Level |
---|---|---|---|
Used | Previously owned; minimal work performed beyond basic power‑on testing. | May lack accessories; cosmetic wear likely; limited or no warranty. | Higher—budget-friendly but verify functionality carefully. |
Patient-Ready | Cleaned, function tested, and fitted with essential accessories/consumables. | Ready to use upon delivery; basic warranty; documentation of checks. | Moderate—good balance of value and readiness. |
Refurbished | Systematically restored: parts replaced, calibration performed, cosmetics improved. | Refurb report; QA checklist; longer warranty; near-new performance. | Lower—ideal for critical applications and uptime needs. |
Certified Pre‑Owned | Refurbished to a published standard and certified by the seller or OEM. | Formal certificate; full PM; software updates; comprehensive warranty. | Lowest—often priced higher but reduces lifecycle risk. |
As‑Is / Where‑Is | No warranty or guarantees; usually untested; buyer assumes risk. | Inspection prior to purchase strongly recommended. | Highest—use only for parts or experienced in‑house service teams. |
Pro tip: Ask sellers to provide their refurbishment SOP (standard operating procedure) and a sample quality checklist.
Cosmetic & Functional Grading
Grading communicates outward appearance and operational status. There’s no universal grading scale, but many dealers use A–D or 1–5 tiers. Insist on photos and test results to back the grade.
Grade | Cosmetic Condition | Functional Status | Typical Use Case |
---|---|---|---|
A / 1 | Like new; minimal wear; clean chassis & screens. | Fully functional; passes all OEM tests. | Frontline clinical use; image‑sensitive rooms. |
B / 2 | Minor scuffs/scratches; normal wear. | Fully functional; minor cosmetic flaws only. | General clinical use; best value for most buyers. |
C / 3 | Visible wear; dents/paint chips possible. | Functional with non‑critical issues (e.g., sticky keys). | Non‑patient areas, backup, or budget-constrained sites. |
D / 4–5 | Heavy wear or damage. | Partial or non‑functional; for parts/repair. | Engineering, training, or parts harvesting. |
Parts, Accessories, and Consumables
- OEM (Original Equipment Manufacturer) Parts: Built by the original brand. Usually best fit/performance; may cost more.
- Aftermarket / Third‑Party Parts: Compatible replacements made by other manufacturers. Validate performance and warranty impact.
- Accessories: Cables, probes, sensors, footswitches, carts, mounting arms—often excluded in “used” listings.
- Consumables: Items with limited life (e.g., filters, electrodes, battery packs). Always budget for replacements.
Request an Inclusions/Exclusions list and a Bill of Materials (BOM) so you know exactly what arrives.
Service History, Calibration, and Preventive Maintenance (PM)
Documentation proves how the device was maintained and that it currently meets performance spec.
- Service History / Logs: Prior repairs, part replacements, and error codes.
- Calibration Certificate: Evidence that measurements (e.g., ECG, NIBP, SpO2, flow) were set to traceable standards with date and due date.
- PM Checklist: Preventive maintenance tasks completed (cleaning, lubrication, firmware checks, safety tests).
- Electrical Safety Test: Leakage current/ground resistance results for patient and operator safety.
Ask for PDFs of the latest calibration and PM, signed by a qualified biomed/engineer, plus the next due dates.
Regulatory & Compliance Labels
Compliance determines where a device can be legally sold and used. Common references you’ll see:
- FDA 510(k): In the U.S., many devices require 510(k) clearance before marketing. For pre‑owned units, ensure the original model has valid clearance.
- CE Marking: Indicates conformity with EU health, safety, and environmental protection standards (EU/EEA).
- ISO 13485: Quality management system certification for medical device organizations (relevant to refurbishers and manufacturers).
- UDI (Unique Device Identification): Labeling that helps track devices through their lifecycle.
- Electrical Standards: Look for compliance marks like UL, CSA, or IEC 60601 testing references.
For cross‑border purchases, confirm voltage/frequency (e.g., 110V/60Hz vs. 220V/50Hz) and plug type, and ensure the software language and region settings are appropriate.
Warranties, DOA, and Return Terms
Warranty length is only part of the story. What matters is what’s covered and response time.
Term | Typical Scope | What to Confirm |
---|---|---|
DOA (Dead on Arrival) | Replacement or repair if the unit fails at delivery or within a few days. | Window length (e.g., 7–14 days), who pays shipping, proof required. |
Parts & Labor Warranty | Seller covers parts and labor for defects during the term. | Exclusions (consumables, user damage), response time, loaners availability. |
Limited Parts Only | Parts supplied; you pay labor/service call. | Labor rates, authorized service centers, turnaround time. |
RTB (Return‑to‑Base) | Buyer ships unit back for repair. | Who covers freight, packing requirements, typical repair SLA. |
On‑Site Support | Technician dispatched to your facility. | Coverage area, response times, weekend/after‑hours policy. |
Ask if an extended warranty or service agreement is available and what preventive visits it includes.
Logistics, Installation & Acceptance
- Freight Terms: Curbside vs. inside delivery, lift‑gate service, white‑glove installation.
- Packaging: Crating, shock/tilt indicators, moisture protection; request photos before shipment.
- Site Requirements: Room size, line power, network ports, HVAC, shielding (imaging), water/drain (sterilizers).
- SIT/FAT (Site/Factory Acceptance Test): Test plan to verify performance after install; signoff document.
- Training: Applications training for clinical users and basic care for biomeds.
Pricing Words to Know
- FOB / Ex‑Works: Price at seller’s dock; you arrange pickup, insurance, and export.
- Turnkey: Price includes installation, training, initial consumables—ready to operate.
- Bundle: Multiple devices or accessories priced together; check unit breakdown.
- Core Exchange: Discount for trading in your old unit; condition of your core matters.
- Lead Time: Days to ship after payment or PO; ask if the unit is in stock or inbound.
Buyer Due‑Diligence Checklist (Save or Print)
- Model and software version match your clinical needs and local regulations.
- Written refurbishment process and completed QA checklist.
- Calibration certificate, PM report, and next due dates.
- Full inclusions list (probes, cables, carts, manuals, power cords, accessories).
- Warranty details: term, scope, response time, loaners, exclusions.
- High‑resolution photos and, if possible, a live video demo or remote test.
- Shipping method, packaging standard, insurance, and delivery appointment.
- Acceptance test plan and training schedule included in the quote.
- Spare parts availability and service coverage in your region.
- Total cost of ownership estimate (consumables, service, software, disposables).
Quick Glossary: Pre‑Owned Medical Equipment Terms
Term | Plain‑English Definition |
---|---|
Acceptance Test | Documented checks performed at your site after installation to confirm performance. |
Asset Tag / Serial Number | Unique identifiers used for tracking service, recalls, and warranty. |
Calibration | Adjusting measurements to meet known standards; comes with a dated certificate. |
CE Marking | Indicates compliance for sale/use in the EU/EEA. |
Consumable | Item that wears out or is used up, like filters or electrodes. |
DOA | Dead on Arrival—policy covering failures at delivery or shortly after. |
FDA 510(k) | U.S. market clearance showing a device is substantially equivalent to a predicate. |
Functional Test | Verifies features work (e.g., NIBP accuracy, imaging performance). |
IFU | Instructions for Use, including safety, operation, and maintenance. |
ISO 13485 | Quality management standard for medical device organizations, including refurbishers. |
OEM | Original Equipment Manufacturer—the brand that designed the device. |
Patient‑Ready | Cleaned, function tested, with necessary accessories to use immediately. |
PM (Preventive Maintenance) | Scheduled maintenance to prevent failures and keep specs within limits. |
Refurbished | Restored via a defined process; parts replaced; cosmetically improved; QA tested. |
RTB Warranty | Return‑to‑Base—you ship the unit back for repairs under warranty. |
Traceability | Ability to track a device’s history (service, parts, calibration, recalls). |
Turnkey | Includes install, training, and items needed to start using the device. |
UDI | Unique Device Identification for lifecycle tracking and safety notices. |
Frequently Asked Questions
What’s the safest condition label to buy?
Certified pre‑owned or clearly documented refurbished devices offer the lowest risk because they include QA testing, calibration, and stronger warranties.
How do I compare two refurbished listings?
Ask for each seller’s refurb process, QA checklist, calibration/PM documents, warranty terms, and a line‑item inclusions list. Compare apples to apples on those documents—not only on price.
Does buying pre‑owned affect compliance?
No, provided the device is compliant for your region (e.g., FDA/CE), installed correctly, and maintained with PM and calibration on schedule. Keep records for inspections and audits.
What should be in an acceptance test?
Verification of key functions, safety tests, image/measurement checks, network integration (if applicable), and a signoff document naming pass/fail criteria and any punch‑list items.
How long should warranties be?
Common terms are 90–180 days for used/patient‑ready and 6–12 months for refurbished/certified. Critical devices or high‑utilization sites benefit from extended coverage.
Conclusion
Clarity beats jargon. When you understand what refurbished, patient‑ready, OEM parts, and DOA actually mean—and you verify those claims with documentation—you reduce risk, control costs, and protect patient outcomes. Use the checklists and tables above during quoting and acceptance to standardize comparisons and get the best value from pre‑owned medical equipment.
Next article: